banner
Products
Speedy delivery
Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24

Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24

Features: Huyssen Power Supply 24V25A AC input 110/220VAC Low leakage current <2mA Protections: Short circuit / Overload;
Basic Info
Model NO. HSJ-600-24
Input Voltage 110-220V
Connection Mode Series Switching Power Supply
Starting Mode Self-excited Switching Power Supply
Voltage Regulating Mode Width Modulation Type
Power Supplying System Terminal Power Distribution Equipment
Energy Transmission One-way Transmission
Modulation System PWM
Certification CE, RoHS, ISO, CCC, FCC
Brand Huyssen
Protections Otp Ocp Ovp STP
Customized Available
Aging Test 100% Full Load Burn-in Test
DC Voltage Adj Range 10%
Material PCB+Steel Box
IP Rating IP20
Applications Power Equipment,LCD Screen, Lighting, etc.
Transport Package Export Packing
Specification 215*115*50mm
Trademark Huyssen
Origin China
HS Code 8504401400
Production Capacity 8500000PCS/Year
Product Description

Features:
Huyssen Power Supply 24V25A
AC input 110/220VAC
Low leakage current <2mA
Protections: Short circuit / Overload / Over voltage / Over temperature
Cooling by fan
Withstand 300vac surge input for 5 second
Conformal coated
LED indicatoLow cost, high reliability100% full load burn-in test
2 years warranty

Specifications:
MODELHSJ-600-24
OUTPUTDC VOLTAGE24V
RATED CURRENT25A
CURRENT RANGE0 ~ 25A
RATED POWER600W
RIPPLE & NOISE (max.) Note.2200mVp-p
VOLTAGE ADJ. RANGE21.6~26.4V
VOLTAGE TOLERANCE Note.3±3.0%
LINE REGULATION ±0.5%
LOAD REGULATION ±2.0%
SETUP, RISE TIME 2500ms, 50ms/230VAC
HOLD UP TIME (Typ.)20ms/230VAC
INPUTVOLTAGE RANGE 90 ~ 132VAC / 176 ~ 264VDC
FREQUENCY RANGE47 ~ 63Hz
EFFICIENCY (Typ.)85%
AC CURRENT (Typ.)1.2A/230VAC 0.6A/230VAC
INRUSH CURRENT(Typ.)50A/230VAC
LEAKAGE CURRENT <2mA / 240VAC
PROTECTIONOVER LOAD105 ~ 140% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE28~30V
Protection type :Hiccup mode, recovers automatically after fault condition is removed
OVER TEMPERATUREShut down O/P voltage, recovers automatically after temperature goes down
ENVIRONMENTWORKING TEMP.-20 ~ +60°C (Refer to derating curve)
WORKING HUMIDITY20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY-20 ~ +85°C , 10 ~ 95% RH
TEMP. COEFFICIENT±0.03%/°C (0~50°C)
VIBRATION10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETYSAFETY STANDARDSU60950-1 approved
WITHSTAND VOLTAGE Note 6I/P-O/P:3.0KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCEI/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25°C/ 70% RH
OTHERSMTBF235K hrs min. MIL-HDBK-217F (25°C )
DIMENSION215*115*50mm (L*W*H)
PACKING0.95Kg; 20pcs/20Kg/0.79CUFT
NOTE1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25°C of ambient temperature.2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.3. Tolerance: includes set up tolerance, line regulation and load regulation.

Related Seires output power supplies:

Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24

Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24

Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24


Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24

Transformer 600W 110V/220VAC to 24VDC 25A Single Output Switching Power Supply S-600-24


Send inquiry